Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ArXiv ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38259341

RESUMO

PURPOSE: This study aims to quantify the variation in dose-volume histogram (DVH) and normal tissue complication probability(NTCP) metrics for head-and-neck (HN) cancer patients when alternative organ-at-risk(OAR) delineations are used for treatment planning and for treatment plan evaluation. We particularly focus on the effects of daily patient positioning/setup variations(SV) in relation to treatment technique and delineation variability. MATERIALS AND METHODS: We generated two-arc VMAT, 5-beam IMRT, and 9-beam IMRT treatment plans for a cohort of 209 HN patients. These plans incorporated five different OAR delineation sets, including manual and four automated algorithms. Each treatment plan was assessed under various simulated per-fraction patient setup uncertainties, evaluating the potential clinical impacts through DVH and NTCP metrics. RESULTS: The study demonstrates that increasing SV generally reduces differences in DVH metrics between alternative delineations. However, in contrast, differences in NTCP metrics tend to increase with higher setup variability. This pattern is observed consistently across different treatment plans and delineator combinations, illustrating the intricate relationship between SV and delineation accuracy. Additionally, the need for delineation accuracy in treatment planning is shown to be case-specific and dependent on factors beyond geometric variations. CONCLUSIONS: The findings highlight the necessity for comprehensive Quality Assurance programs in radiotherapy, incorporating both dosimetric impact analysis and geometric variation assessment to ensure optimal delineation quality. The study emphasizes the complex dynamics of treatment planning in radiotherapy, advocating for personalized, case-specific strategies in clinical practice to enhance patient care quality and efficacy in the face of varying SV and delineation accuracies.

2.
Phys Rev Lett ; 128(25): 252002, 2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-35802440

RESUMO

We report high-precision measurements of the deeply virtual Compton scattering (DVCS) cross section at high values of the Bjorken variable x_{B}. DVCS is sensitive to the generalized parton distributions of the nucleon, which provide a three-dimensional description of its internal constituents. Using the exact analytic expression of the DVCS cross section for all possible polarization states of the initial and final electron and nucleon, and final state photon, we present the first experimental extraction of all four helicity-conserving Compton form factors (CFFs) of the nucleon as a function of x_{B}, while systematically including helicity flip amplitudes. In particular, the high accuracy of the present data demonstrates sensitivity to some very poorly known CFFs.

3.
Phys Rev Lett ; 127(15): 152301, 2021 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-34678020

RESUMO

We report measurements of the exclusive neutral pion electroproduction cross section off protons at large values of x_{B} (0.36, 0.48, and 0.60) and Q^{2} (3.1 to 8.4 GeV^{2}) obtained from Jefferson Lab Hall A experiment E12-06-014. The corresponding structure functions dσ_{T}/dt+εdσ_{L}/dt, dσ_{TT}/dt, dσ_{LT}/dt, and dσ_{LT^{'}}/dt are extracted as a function of the proton momentum transfer t-t_{min}. The results suggest the amplitude for transversely polarized virtual photons continues to dominate the cross section throughout this kinematic range. The data are well described by calculations based on transversity generalized parton distributions coupled to a helicity flip distribution amplitude of the pion, thus providing a unique way to probe the structure of the nucleon.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...